Applies To | |||
Product(s): | AutoPLANT Isometrics; Auto-Iso | ||
Version(s): | V8i | ||
Environment: | N/A | ||
Area: | N/A | ||
Subarea: | N/A | ||
Original Author: | Bentley Technical Support Group | ||
Overview
Dimension style settings can be specified in the ISOTMPL.DWG file in the project. However, some of these settings such as units and precision are ignored when running Auto-Iso.
Auto-Iso ignores or overrides certain settings in the specified Dimension Style
Some settings are stored locally. These can be changed in Project Administrator.
- Open Project Administrator.
- Go to the menu: Edit > Units Configuration...
- Adjust LUPREC and DIMDEC to change precision for UNITS and the Dimension Style.
- These should be adjusted on each workstation where Auto-Iso will be used.
Some of these values are also defined in the Project Administrator Help file.
See Also
Product TechNotes and FAQs
External Links
Bentley Technical Support KnowledgeBase
Comments or Corrections?