It looks like this is possible is the loads are small enough. What version are you using?
↧
Forum Post: RE: How can Staad Foundation Advanced design the pile cap with only one pile under it?
↧
Forum Post: RE: How can Staad Foundation Advanced design the pile cap with only one pile under it?
I am using Version 8.3.0.20. The loads are not too big but not too small neither.
↧
↧
Forum Post: RE: How can Staad Foundation Advanced design the pile cap with only one pile under it?
The loads are small enough to provide single pile for sure. I tried to increase the pile capacity to very large numbers but still couldn't get anything for single pile arrangment result.
↧
Forum Post: RE: VBA Reading Error with Chinese Language
Hello Nikhil, Actually Jon had told you the solution -- you should set the Windows' locale to Chinese (Simplified,PRC) as well. In my box (almost all Chinese people set their Windows' locale to Simplified Chinese, include me ), I add a MsgBox sentence in your code to display the result as below: How to set Windows' locale ? Please see the below pic: HTH, YongAn
↧
Forum Post: RE: [V8i or CONNECT] Generate List of Icons in .dgnlib
I assume you are searching a programmable approach, right? For this, I don't know. If you can accept manual operation, you can try the customization GUI shown as below. I remembered it really can extract all icons in rsc file (include dgnlib file also) into external files. Then you can import them into a new dgn file. HTH, YongAn
↧
↧
Forum Post: RE: Is there a video or other example of using the Data cleanup to identify overlaps (current MicroStation Connect and or V8 versions)?
I don't get that behaviour works fine for me, have you set the flags and overlap tolerance? my default is 0.010 ( I think its in master units)
↧
Forum Post: RE: Pipe Crossover/hook-up device tools not working
Hi Satadal, I am connecting horizontal pipe runs (no slope) using place pipe tool, I am not interested in crosses but crossovers . I remember using it in previous project (not sure if it was SS5 or SS6). My current company/project is on SS6 so CONNECT edition is not an option. Regards, Azhar
↧
Forum Post: RE: CC surface constraints
Hi Oto: I agree with you. One additional question; how to determine if the model is "slanted" My metadata has valid gps coordinates and orthometric heights. Why can't I use these instead of running automatic vertical and then adding control points. If this is the only solution then I don't have to bother with collecting metadata with my images Farouk
↧
Forum Post: RE: File is too big to manage... How to reduce size?
I'm not sure why, but the file(s) will not upload for me. I instead am attaching a link to the file in Dropbox. Please let me know what you think. We have resorted to making shop drawings by hand because the file is too large to process drawings in express. Thanks. Bernie www.dropbox.com/.../From small to Big.zip
↧
↧
Forum Post: Run time error '11' division by 0
Hi i'm trying to set up roofs and keep getting the error code run time '11'. Division by 0. I got our IT department to install the latest graphic drivers, however the problem is still occurring. It is quite a complex roof drawing. Could this be the problem?
↧
Forum Post: ORD U3 - Crashes While Creating Geometry
Hi, I'd like to get an idea of how many other people, if any, are experiencing crashes while creating / editing civil geometry. What I am experiencing now is no where near as bad as it used to be but I am noticing that 90% of the crashes I experience now occur when I am working with civil geometry. When possible I submit the exceptions log but every now and then ORD hangs and the closes itself with no crash or submit exceptions log window at all. The event logs details module ucrtbase.dll as being faulty, is anyone else experiencing this? Josh
↧
Forum Post: RE: Corridor Modeling Crash
Not sure if this will help but you wouldn't happen to have made small edits to your template? I've experienced a similar crash and the cause was the use of buggy feature definitions in the template. Whats the size of your terrain file? I'm not sure your project files are attached, I can't see them.
↧
Forum Post: RE: Is there a video or other example of using the Data cleanup to identify overlaps (current MicroStation Connect and or V8 versions)?
Yes, what these guys said. I would take some small file(s) and do some quick tests. For overlaps, you may find the Interactive mode works best. It highlights and annotates (temporarily) each overlaps, allows you to repair it, then you can continue to the next overlap.
↧
↧
Wiki Page: ProStructures V8i SELECTseries 6 R2 for AutoCAD ReadMe
AutoCAD 2017 Service Pack 1 Version v08.11.11. 2xx Operating Systems Microsoft Windows Microsoft® (see Requirements for specific details) Language English Before you begin, please note the following: Review the End-User License Agreement (or EULA) carefully during the installation of ProStructures V8 i . By installing this release, you agree to the terms and conditions of the agreement. Prerequisite There is an issue with hideDisplay API of Body class in AecModeler in AutoCAD 2017. Please follow guidelines from http://adndevblog.typepad.com/autocad/2016/07/aecmodeler-and-autocad-2017-service-pack-1.html for a valid solution. Alternatively, after installing ProStructures V8i SS6 R2, you may copy AecModeler.dbx from C:\Program Files\Bentley\ProStructures Ss6 R2\AutoCAD 2017\Prg to C:\Program Files\Autodesk\AutoCAD 2017 (remember to backup original AecModeler.dbx) It is required to have AutoCAD 2017 Service Pack 1 installed on the system prior the installation of ProStructures V8i SELECTseries 6 R2. Before installing ProStructures V8 i , be sure to fully read this document as well as the Requirements and QuickInstall documents , which contain critical information about the installation. Please also consult the Bentley Web site for the latest information on this and other Bentley products. This document contains the following information: Release Notes Installation Notes AutoPlant users ProStructures object enabler Publishing ProStructures AutoCAD 2017 files to i-Model Support and Services Information BE Communities Support Path Back to top Release Notes The only changes to this release is the addition of Bentley Cloud services support for more information visit this site Back to top Installation Notes ProStructures V8 i *should not* be installed on the same workstation as an existing ProStructures V8 i v08.11.xx Technology Preview (“beta”) release(s). Installing ProStructures V8 i over an existing ProStructures V8 i v8.11.xx beta installation can cause incompatibilities and data loss. You must uninstall the beta release, and then install the commercial release. Install Bentley Structural to a separate directory. You should always back up your data prior to installation. ProStructures SS6 R2 (08.11.11. 2xx ) is not an update release to SS6 R1 (08.11.11.132), hence it can coexist alongside previous SS6 installation on the same system. It is advisable to backup any customized files before uninstalling any existing ProStructures version. ProStructures is only upward compatible, dwg files are automatically converted/upgraded to the new version, once upgraded, ProStructures objects will no longer display correctly if opened on any prior version of the software. Therefore it is advisable to make a backup copy if opening the file in its earlier version is anticipated. For additional information on installing ProStructures V8 i , see the ProStructures V8 i QuickInstall Guide. Back to top AutoPlant users: When encountering Pipe.mnl file loads security concern message popup at ProStructures startup after AutoPLANT session is closed or any file loading security concern message at startup: Solution: 1. Run the options command 2. Select the ProStructures user profile 3. Go to trusted locations 4. Under Trusted location, Add path C:\Program Files (x86)\Bentley\Plant V8i\Piping 5. It will not pop-up the file loading security concern message, the next time. Back to top ProStructures object enabler: when encountering ProStructures dbx file loading security concern message Solution: 1. Start AutoCAD 2. Run the options command 3. Go to trusted locations 4. Add the object enabler folder path C:\program files\bentley\prostructures\objectenabler\autocad 20xx folder. General Workaround: 1. In Command prompt, run SECURELOAD command 2. Enter new value for SECURELOAD '0', by default it is 1 3. Restart the session 4. It will not show any file security loading concern message at startup Back to top Publishing ProStructures AutoCAD 2017 files to i-Model: 1. download and install i-Model runtime for AutoPlant 2. download and install ProStructures plugin for Bentley product Back to top Support and Services Information TechNotes, FAQs, and additional Bentley product information can be found on the Product TechNotes and FAQs page provided by the Bentley Technical Support Group as well as the Bentley Library . You can efficiently log issues that you encounter in Bentley products with the Service Request Manager . Information on other professional support and service offerings from Bentley is available online at SELECTservices Online . Back to top BE Communities Meet other users of Bentley products, exchange ideas, and discuss a wide range of technical subjects in the BE Communities. BE Communities can be accessed via a Web browser and are a good source of how-to tips, technical information, and programming techniques from Bentley employees and professionals who use our products. Click here to connect with the Structural Drafting and Detailing Community Forum . Back to top Support Path With ProStructures V8 i , you are required to establish a Support Path (previously known as Registration). This Support Path connection is a one-time procedure in the form of a Web page when you open ProStructures V8 i . Once the Support Path has been established, the Help > Online Support link in ProStructures V8 i becomes active. This link gives you access to the Support page. Through the Support page you can manage your profile and depending on your level of support: access TechNotes and FAQs; share information on Discussion Groups; search the product KnowledgeBase; submit, monitor, and track online service requests; participate in live online chat regarding support issues; and use the latest technologies to share your desktop with a Support Engineer. Whether or not you see the Support page depends on one of the following scenarios: If you have not activated the product, you will not see the Support page. This means you have never contacted SELECTserver on that computer since installing the product. In this case, the product is in 30-day countdown mode. If you have registered an earlier version of ProStructures V8 i , you will not see the Support page. The information is maintained from previous versions. If you have activated the product but never registered, you will see the Support Page when you open ProStructures V8 i . This page will come up once a week as a reminder. After three weeks, you will be given the opportunity to turn the Web page off. After 10 weeks, it will turn off by itself. After you register, the information is recorded on SELECTserver and you will not see the Support page on any computer connected to SELECTserver. Back to top
↧
Wiki Page: ProStructures V8i SELECTseries 6 R2 for AutoCAD Product activation
Product activation is achieved by connecting to a SELECTserver, receiving verification that your SELECTserver Name and Activation Key are correct, and successfully posting Usage logs. Product activation is not the same as checking out a license. This document describes how to configure ProStructures V8 i SELECTseries 6 R2 for activation. After initial configuration, ProStructures V8 i SELECTseries 6 R2 automatically and transparently tries to activate each time it runs, and runs unconstrained for a period of 30 days after its last successful activation. However, if activation is unsuccessful for a period of 30 days, ProStructures V8 i SELECTseries 6 R2 runs in unauthorized mode with sessions limited to 15 minutes until the product is successfully activated again. Important note : If the workstation on which ProStructures V8 i SELECTseries 6 R2 will be running does not have regular network access for periodic activation (at least every 30 days), then consider utilizing a checked-out license. Checked-out licenses are considered to be in full-time use and ProStructures V8 i SELECTseries 6 R2 will not attempt to post usage for the duration of the license term. See the ProStructures V8 i SELECTseries 6 R2 documentation for details on obtaining a checked out license. Activating a product using the Product Activation Wizard After a product is installed, you must obtain a license and then activate that license. The Product Activation Wizard steps users through the product activation process. The Product Activation Wizard opens automatically at the end of the product installation, assuming you turned on the "Launch the Product Activation Wizard" option on the final page of the installation wizard. See To install this product in the ProStructures V8 i (SELECTseries 6) QuickInstall Guide for more information on installing ProStructures V8 i SELECTseries 6 R2. You can also access the Product Activation Wizard from within ProStructures V8 i (SELECTseries 6) by selecting Utilities > License Management > Tools > Options or Utilities > License Management > Tools > Product Activation Wizard. See the License Management Tool documentation in the ProStructures V8 i Help for more information. The Product Activation Wizard offers four product activation options: SELECT subscribers activating against a hosted (Bentley) SELECT Server SELECT subscribers with a deployed (local) SELECT Server NON-SELECT or Node Locked user Evaluation Only - No license information The wizard will then step you through the activation process based on the option selected. Back to top SELECT subscribers activating against a hosted (Bentley) SELECT Server If you are activating against a hosted (Bentley) SELECT Server, the Server Name is pre-populated but you must provide the proper Activation Key provided by the Bentley Sales Support Center . Select the option, SELECT subscribers activating against a hosted (Bentley) SELECT Server, then click Next. The Activating against a SELECTserver page opens. Enter the site activation key in the Site Activation Key field. If you are using HTTPS, turn on the HTTPS (SSL) option. If you are using a Proxy server to connect to the hosted SELECT Server, click the Proxy button and fill in the Proxy Server information then click OK. Click Test Connection to verify the connection to the SELECT Server. Click Next. The Country of Use page opens. Select the country where you will be using this product and click Next. The Wizard Selections page displays the information provided on the previous pages. Review the information and click Finish to activate the product. Back to top SELECT subscribers with a deployed (local) SELECT Server If you are activating against a local SELECT Server, you must provide the proper Server Name and Activation Key. The Server Name and Activation Key, along with any proxy configuration information, can be obtained from your Site Administrator. Select the option, SELECT subscribers with a deployed (local) SELECT Server, then click Next. The Activating against a SELECTserver page opens. Enter the name of the server in the Server Name field. Enter the site activation key in the Site Activation Key field. If you are using HTTPS, turn on the HTTPS (SSL) option. If you are using a Proxy server to connect to the hosted SELECT Server, click the Proxy button and fill in the Proxy Server information then click OK. Click Test Connection to verify the connection to the SELECT Server. Click Next. The Country of Use page opens. Select the country where you will be using this product and click Next. The Wizard Selections page displays the information provided on the previous pages. Review the information and click Finish to activate the product. Important note for System Administrators using SELECTserver 2004 Edition : ProStructures V8 i SELECTseries 6 R2 requires SELECTserver XM Edition or newer and will not run with SELECTserver 2004 Edition (V8.5.2 and earlier). The latest SELECTserver can be obtained from the Downloads/MySELECT CD area of SELECTservices Online . You need to obtain a new license file for SELECTserver. Contact the Bentley Sales Support Center that services your area for information on upgrading your current SELECTserver 2004 Edition license file. Back to top NON-SELECT or Node Locked user If you are not a Bentley SELECT subscriber and you are activating ProStructures V8 i (SELECTseries 6), you are presented with three options: I have a license file ready to import Enter the path to and including your license file name in the License File field, or click Browse to select the license the file to import. Click Next. The Wizard Selections page displays the information provided on the previous page. Review the information and click Finish to activate the product. I have an activation key Enter the site activation key in the Site Activation Key field. If you are using HTTPS, turn on the HTTPS (SSL) option. If you are using a Proxy server to connect to the hosted SELECT Server, click the Proxy button and fill in the Proxy Server information then click OK. Click Test Connection to verify the connection to the SELECT Server. Click Next. The Check out license now? page displays. Enter your Email address in the Email Address field. Select the product to be activated (if not pre-populated) it the Product Name field. Enter the product version number (if not pre-populated) in the Product Version field. Click Next. The Country of Use page opens. Select the country where you will be using this product and click Next. The Wizard Selections page displays the information provided on the previous pages. Review the information and click Finish to activate the product. I do not have any license information The product will run in evaluation mode. Click Go To Bentley.com to request activation information. Back to top Evaluation Only - No license information The product will run in evaluation mode. Click Go To Bentley.com to request activation information. Back to top
↧
Wiki Page: ProStructures - what is new
The following links provide access to other Wiki pages where lists of enhancements and fixes for each ProStructures release is found.. Follow the links below (for English): Announcing ProStructures V8i SELECTseries 6 R2 (08.11.11.2 xx ) for AutoCAD Announcing ProStructures CONNECT Edition Update 1 (10.01.00. xx ) Announcing ProStructures CONNECT Edition (10.00.00.74) Announcing Prostructures V8i SELECTseries 8 update 2 (08.11.14.238) ProStructures V8i SELECTseries 8 update 1 (08.11.14.225) now available on Bentley Software Fulfillment Center ProStructures V8i SELECTseries 6 R1 (08.11.11.161) for AutoCAD is now available on Bentley Software Fulfillement Center ProStructures V8i SELECTseries 8 (08.11.14.195) now available on Bentley Software Fulfillment Center ProStructures V8i SELECTseries 6 (08.11.11.132) for AutoCAD now available on Bentley SELECTserver PowerProStructures V8i SELECTseries 7 (08.11.11.616) now available on Bentley SELECTserver ProStructures V8i SELECTseries 6 (08.11.11.87) for AutoCAD now available on Bentley SELECTserver PowerProstructures SELECT Series7 (8.11.11.297) now on SELECTserver ProStructures V8i SELECTseries 6 (08.11.11.45) - on Bentley SELECTserver ProStructures V8i SELECTseries 5 (08.11.10.36) 32 bit for MicroStation - on Bentley SELECTserver ProStructures V8i SELECTseries 3 (08.11.03...) 32 bit - on Bentley SELECTserver ProStructures V8i SELECTseries 3 (08.11.03.35) 64 bit - on Bentley SELECTserver ProStructures (ProSteel and ProConcrete) V8i SELECTseries 2 (08.11.02.18) - posted on Bentley SELECTserver ProSteel V8i SELECTseries 1 (08.11.05.43) - posted on Benley SELECTserver Einfach den unten aufgefuehrten Link folgen (Deutsch): ProStructures V8i SELECTseries 3 (08.11.03.xx) 32 und 64 bit - jetzt auf Bentley SELECTserver ProStructures (ProSteel und ProConcrete) V8i SELECTseries 2 (08.11.02.18) - jetzt auf Bentley SELECTserver
↧
Wiki Page: DGN reference files in DWG work mode
Product(s): MicroStation Version(s): 08.11.09.869 Environment: N\A Area: DWG Subarea: General Problem When in DWG work mode and having DGN files attached as reference, on opening the master file MicroStation comes with a message in the Message Centre, stating: DGN Reference "...\ReferenceDGN1.dgn" has been substituted for "ReferenceDGN1.dwg" The DWG reference file: "ReferenceDGN1.dgn" could not be found - "...\ReferenceDGN1.dgn" has been substituted for this attachment. This behaviour is expected when a DGN file is attached as a reference to a DWG file as it is not possible to store the DGN name in a DWG attachment. When working with a Document Management System, this could lead to all kind of problems. Solution There is no solution to solve this issue as it is a Works As Designed. However, it is possible to prevent attaching DGN files as reference while working in DWG work mode in MicroStation. This can be done by adding the capability statement _USTN_CAPABILITY_DWG > -CAPABILITY_REFERENCE_V8 to ...\Bentley\MicroStation V8i (SELECTseries)\MicroStation\config\system\workmode.cfg Before making any changes to the configuration file, please make a copy to use as backup. See Also
↧
↧
Forum Post: RE: View Attributes
Thanks Steve i adjusted my project search path, closed the file and re-opened and that fixed the problem
↧
Forum Post: importing rfa files into aecosim
perhaps i have misunderstood the tools to do this i tried the RFA interpreter wizard, selected a family of parts selected a folder of parts, at this stage the Bentley warnings say: the next button showed all the parts the next button showed: at this stage the next button is greyed out i think the root of the problem is that failed to create a 3d element these objects are being used on revit projects in the same office and were created by for use on company projects they are 3d, but it seems cannot be imported into aecosim am i missing some vital part of the routine for successful conversion of rfa files?
↧