Forum Post: Re: Conflict version? Bentley AutoPlant V8i SS3 Piping and old...
Hi.. yes, old project was done in ss2. but now company uses ss3. drawings are still in the project. i can open it from document manager. but piping is not load when i open it.
View ArticleForum Post: Re: Bom Explorer/Bom import
Hi Brian. There's not really a lot of formatting of the spreadsheet required because you will map the columns of the spreadsheet to promis•e attributes during the import. This mapping can also be...
View ArticleForum Post: Re: Error in code
Hi, Thanks to everyone especially(Jon, stefan, Jan, Mark and Chris) who has helped me to solve the errors.Regards,Saran.
View ArticleForum Post: Re: StormCAD - Adding flow to a manhole
Hi Rob, After double checking on this I think I see why you may be a little confused. It looks like the features that I described are new features in StormCAD Select Series 3 (08.11.03.77), which can...
View ArticleForum Post: Re: StormCAD - Pressure Sewer
Rob,It depends on what you are trying to solve for.1. If you just want to see what the level will be in the system in dry weather with backup from the tailwater, then don't put any loading. In that...
View ArticleForum Post: AECOSIM Analyze Route not working
Hello,I'm having difficulty using the Analyze Route tool for HVAC analysis. I've modeled a duct system, with supply and return ductwork and a supply fan.When I try to use the Analyze Route tool while...
View ArticleForum Post: Re: StormCAD Dimensions in Inlet Catalog
It looks like I might have been incorrect in some of the information that I gave you. I double checked with one of our developers to make sure I understand what all the dimensions are. The information...
View ArticleForum Post: Re: Error creating file
Thanks.Problem was a bad installation of ss3 over ss2. I think it was trying to use ss2 RealDWG2010.Uninstalled everything and did a clean install of ss3 - now works.
View ArticleForum Post: Re: Grayscale vs Screening
When grayscale is selected, the resolved print color is gray shade arrived at by the formula 30% R + 59% G + 11% B, where R, G, and B are the red, green, and blue input color components.Screening is a...
View ArticleForum Post: Re: SS3 Ditch profile design issues
The changes to how linear targets are defined in SS3 were done for various reasons. First, All linear targeting (H/V/Both) can only be accomplished by using Target Aliasing. We found during extensive...
View ArticleForum Post: Pre-Smartgeometry GC workshops in London next week
Before the upcoming Smartgeometry event in London we offer two workshops for GC next week:April 9 and 10, starting at 9 AMGC basic/refresherLocation: University College LondonRoom for April 9:...
View ArticleForum Post: Re: Microstation first renders - back to the past
Version 4 render using Pixar's Renderman plug-in
View ArticleForum Post: Re: PowerSurvey V8i SS2 / .XIN - Text Nodes from Custom Operators?
As a Select Member you will find the Ticket Manger here:selectservices.bentley.com/en-US
View ArticleForum Post: Re: Location of Markers
I took a little time to try the Create Floor Plan, Floor Plan by Floor Set option. Structural model example.The markers use the centroid of the clip volume (the extents of the components on that floor...
View ArticleForum Post: Re: Roadway Designer Component Styles
In SELECTseries 2 the template components for MX are driven by a specified cross section pss defined in MX.cfg. By default this is set to Roadway Designer section components.pss. You can redefine the...
View ArticleForum Post: Re: 'Place Note' Text Weight
"Dimension" is both a class and an element type. As an element type, it's what's referred to as a "compound element", similar to but not quite the same as a complex string or shape.In the DGN file,...
View ArticleForum Post: Re: Cla-Val Control Valves in Water Hammer
Thanks Jesse, I didn't even consider the D2A option. I'll test that out with some other sensitivity analyses. You've been very helpful!-BWhite
View ArticleForum Post: Re: ABD trashing structural rules file
Is the .rule file that gets stripped to 1KB from ABD 08.11.09.376 version or is the rule file from a previous version?
View ArticleForum Post: Re: SewerCAD HGL Profile Error
Sometime when the pipes are long, they need be divided into bunch of sections for calculation purposes so that output is more accurate. In this case, one can try changing profile steps in the...
View ArticleForum Post: Re: Extractions not unifying
Nick,We have experienced the same problem on larger and denser models.In the 'Preferences' tab of the DEM manager try setting the UOR (Unit of Resolution) to a higher number.(Refer to appended...
View Article