Forum Post: Deflection Check to Beam with Intermediate Nodes
What is the fastest way to assign the deflection criteria to the beams with intermediate nodes?So far I was assigning DJ1 and DJ2 to the end nodes and DMAX to the members between end nodes. But this is...
View ArticleForum Post: Re: Pipe - AISC 360-10 Eqn H3-6
In the implementation of equation H3-6, for the term Mr, the value of MZ is curently being used. The ambiguity is arising from the fact that in H3-6, the code has not explicitly stated what to use for...
View ArticleForum Post: Re: Strength / Serviceability Member Design
Yes, the method I suggested is applicable for member selection too.
View ArticleForum Post: Re: Selecting elements on same level in one click
Thanks hUbs,I couldn't get this to work earlier but then found that the elements I was trying to select in the sheet space were referenced from the model. It wasn't until I activated the reference that...
View ArticleForum Post: Re: Black shadows
Hello,Using the Render setup "Ray Trace" will get you the desired effect.Or you can Disable Global illumination > Indirect illumination from Render setup will give you dark shadows .If GI is Off...
View ArticleForum Post: Re: light in 3dpdfs
Hello,Looks like you have the solar light ON. If you turn that OFF , OR Set "Default Light" = ON from the view you will get uniform lighting. Thanks & RgHarshad
View ArticleForum Post: Draw Cross Section from Surface - Missing Lines
Not a good day for me and Roadway Designer... I created a model from Corridor Modeler and created a DTM from it. When I use the "Draw Cross Sections from Surface" tool, for some reason it doesn't draw...
View ArticleForum Post: Re: Dynamic views & hatching
Abe, it seems what you're looking for is Dataset Explorer - this is where Family and Part attributes are defined. After you copy the S-G22-SlabConcreteprecast part, in the new version turn Fill off...
View ArticleForum Post: Re: Problem resymbolization style line in structural
So it's only the linestyles generated via a drawing rule that seem to be affected?
View ArticleForum Post: Survey Directions - What Are the Long Term Goals
This is a response to Lou's questions from another post (http://communities.bentley.com/products/road___site_design/f/5922/t/85870.aspx) which I did not start, but did put in my $0.02. So rather than...
View ArticleForum Post: Re: Building View Workflow Clarification
Tom's ticket was handled from a MicroStation perspective vs. ABD or BA, but it looks as though everything was tied into changing the Display Overrides reference setting on the Sheet to 'Never'....
View ArticleForum Post: Re: Resymbolization beams
Try changing the Double Line to less than 100% of member length. I think you may be seeing the double line "widget" represented as the entire length of the beams.
View ArticleForum Post: Re: Parts, and the tyranny of dgnlibs
^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ ^ From the DataGroup Catalog Editor, the Part Definition property defines the Family:: Part used by that specific catalog item (walls in this case). So...
View ArticleForum Post: quick run down of advantages of iplot
Our company is considering switching to IPLOT but it is a big investment and I personally don't see enough benefit from it compared to what we are doing now.We batch print everything now, which is the...
View ArticleForum Post: Re: Component Centerlines
Hi Phil, your question would be better suited for the Plant Design and Engineering forum @ communities.bentley.com/.../5927.aspx
View ArticleForum Post: Component Centerlines
Hello,I am in the process of reprogramming the cable-tray portion the Raceway module for AutoPLANT. Part of this is changing how some of the centerlines are displayed on some components. I am able to...
View ArticleForum Post: Re: Black shadows
Thanks for your replies. Raytrace is getting to closer to what I'm looking for. How do you turn off Global Illumination and is this the same as un-ticking 'illuminate both sides of surface'?So far I am...
View Article