Forum Post: RE: Using a Cell as a Pattern not working for certain cells

$
0
0
Daniel Firstly can you indicate which version of MicroStation (xx.yy.zz.000) or add on you are using Secondly you have not attached the cel library for any testing to be undertaken Ian

Wiki Page: Run time error 429 or Unexpected Error; Quitting message

$
0
0
Product(s): Bentley Hevacomp Version(s): V8i (V26.xx.xx.xx) Environment: N/A Area: N/A Subarea: N/A Disambiguation If you receive a run time error 429 with this associate screen corruption then please see this document instead. Problem During the installation a lack of permissions have stopped components being registered correctly. You should not normally need to reinstall the software Solution Check to see that the run time components are installed. Open Control Panel and select Uninstall a program: From the list of available programs see if you can identify the following. Do not uninstall anything. For Version 26 installations: Run Time Components for Bentley Hevacomp V8i 25.xx.xx.xx -or- Run Time Components for Bentley Hevacomp V8i 26.xx.xx.xx If any of these items do not exist for the relevant version, then consult this document to ensure you have a full and clean installation of the software. Once we have ascertained we have the components installed correctly, navigate into the installation folder: With 32bit Windows: C:\Program Files\Bentley\Hevacomp V8i\Hevacomp\ With 64bit Windows: C:\Program Files (x86)\Bentley\Hevacomp V8i\Hevacomp\ In this folder, locate these five programs: Hevbanner.exe HevenergyPlus.exe DDB.exe Netsys.exe Nimbus.exe For each program in turn, right click on them and select Run as administrator from the context menu. If required, provide an administrator password. If you receive an onscreen message after running one of the programs, ignore the message. If the program opens, close it using normal methods. Once all of the programs have been run in this manner you should be able to run your software correctly from the Bentley Hevacomp V8i icon, or from the Start menu link.

Forum Post: RE: Using a Cell as a Pattern not working for certain cells

$
0
0
Ian, I am using Power InRoads V8i SS2 - Version 08.11.07.615 The cells should be contained in the Pattern.dgn in separate model spaces.....Idk if this is causing the problem, but that is how we set up our cell files. Thanks.

Forum Post: RE: IP address needed for the Licence,

$
0
0
Many thanks Gary, my colleagues in Licensing will be able to assist with this so I will log it with them now. You should hear from them shortly.

Forum Post: RE: LRFD LOAD COMBINATION WITH NOTIONAL LOAD

$
0
0
Yes the REPEAT LOADs have been specified correctly. The PDELTA analysis command is PDELTA nn ANALYSIS or PDELTA nn ANALYSIS SMALLDELTA ( both are the same ) where "nn" stands for the number of iterations. Using about 20 iterations is fine. In other words you can use PDELTA 20 ANALYSIS or PDELTA 20 ANALYSIS SMALLDELTA as the analysis command.

Forum Post: RE: NOTIONAL LOAD

$
0
0
Yes you should get the same results. However a better way of handling this is the way you mentioned in the post below https://communities.bentley.com/products/ram-staad/f/ram-staad-forum/177175/lrfd-load-combination-with-notional-load

Forum Post: RE: Introduction to Descartes

$
0
0
Thank you, I have seen this video, but I cannot see at the resolution its filmed at what the command set being used is. Regards Phil

Forum Post: RE: ASCE 7-10 WIND LOADING ANALYSIS-MWFRS-CALCULATION METHOD

$
0
0
ASCE 7 is a load generation code and not a design code. So when it comes to wind or seismic load generation or generation of automatic load combinations ( IBC refers to ASCE ) you would be able to select this code. However when it comes to design, it would be AISC (for steel) or ACI (concrete) etc.

Forum Post: RE: printing specific data in a Staad.pro Report

$
0
0
The steel design does not pick up the steel grade from material definition. You will need to specify the design parameter SGR for that. In your file, if you assign the SGR 2 to all the members ( command is SGR 2 ALL ), you would get the results you are looking for.

Forum Post: RE: [ERROR] NO LOAD CASE INCLUDED IN THE JOB IS DEFINED AS 'DESIGN LOAD CASE in STAAD Foundation Advanced

$
0
0
Go to Job Setup > Edit Current Job and ensure that you have load cases under the Selected Load Cases window on the right. After you do that ensure that you click on the Edit Current Job button below the window. You should have both service and ultimate load combinations within the Selected Load Cases window.

Forum Post: Aecosim Building Designer V8i V8i 08.11.09.829 and ProjectWise Explorer 10.00.2265

$
0
0
Hi everyone, I'm using Aecosim BD V8i and ProjectWise explorer 10.00.2265. When I open a Aecosim file through ProjectWise the Dataset doesn't load: Any ideas? Compatibility issue between the 2 versions? Thanks for your help

Forum Post: RE: MicroStation CONNECT - measure area different values

$
0
0
I have seen this happen if the files have different coordinate systems, when copying a shape into another file there is a scale factor that you may/may not have noticed (maybe do a reference then merge with master), your design file units/subunits may not match, your working units accuracy may be different in both files, ensure that you are using the same settings for the measure command as well. Considering that this is a 2D drawing, you can narrow it down quite a bit I think! I guess I gave a lot of suggestions here... I hope one of those works out.

Forum Post: RE: Gusset Base Plate Connection

$
0
0
I reviewed your files (Rack 3.std). It does look suspicious how different the two column base plates are. In order to diagnose things I made some simplifications to the model. I made it a 2-D frame that was basically symmetric and I checked the connection design for just a few load combinations. When I assign the connections anew, then the results are also symmetric as I would expect. My test was with version 22.00.00.15 of STAAD.pro. I don't see anything obvious in the original to account for the differences, but when I compare the two reports side by side I see various differences, in the materials, loads grout thickness, etc. Try updating to the latest version and re-assigning the Gusset Base Plates and let me know if the issue persists for you. Also note, be sure to use LRFD design for Base Plates to get all the anchor checks.

Forum Post: RE: KMZ File in Google Earth missing elements from model

$
0
0
Hi Ivan, To investigate this issue, we need test data and screenshot of settings set in 'Google Earth Settings' dialog. Thanks for reporting, Manoj

Forum Post: RE: MicroStation CONNECT - measure area different values

$
0
0
Hi Bjorn, To investigate this issue properly, we need a test data and detail steps to reproduce. Thanks for reporting, Manoj

Forum Post: RE: STAAD Pro w/Ram Connect Crashing

$
0
0
if you have designed some connection on ram connection at any node you must clean the connections on ram connection program through the staad.pro

Forum Post: RE: LumenRT - Material Creation

Forum Post: RE: export parametric cell to IFC, when file is on reference IFC is empty !!

$
0
0
Hi, I did a SR four month ago about exporting dgn with parametric cells to IFC. Defect 980821. I guess it's the same issue you're experience. I really hopes this will be fixed in U5.

Forum Post: RE: Help: Prostructure Detail Centre parts/views not processing/inserted/moved to Views Tab

$
0
0
the color coding tells you in which state the details are for processing Grey means the parts have not been processed. The reason why this could be the case, can be various, like a restricted style. As said below, we will need your model for a full conclusion on the issue.

Forum Post: RE: Drawing Tools Not visible when drawing/drawn?

$
0
0
Also, turn off Clip Front/Back/Volume in View Attributes. HTH, Manoj